Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1117TIE-TRK (Tie Trunk)
3
7, FAIL The conference capabilities of the port failed (Error Code 7).
129, The reflective 404-Hz Tone Test failed. No transmission was detected to or
from the port (Error Code 129).
131, or The reflective 1004-Hz Tone Test failed. No transmission was detected to
or from the port (Error Code 131).
133 The reflective 2804-Hz Tone Test failed. No transmission was detected to
or from the port (Error Code 133).
Proceed as follows unless power or tone problems are suspected (see
notes on the next page).
1. To make sure the problem is on-board, disconnect the port from the
CO and retry the test. Coordinate this with the CO, or do it after busy
hours; otherwise, the CO may put the connection out of service.
2. If the retry fails, replace the circuit pack.
3. If the retry passes and no troubles have been reported, disable the
test. If the retry passes and troubles have been reported, refer the
problem to the CO.
NOTE:
If the looparound and conference circuit test fails for all ports on a
circuit pack, a -5 volt power problem is indicated.
If the test fails on more than 1 port, check for errors on the TONE-BD or the
TONE-PT. If errors, take appropriate actions. When the tone errors are
cleared, rerun the test. If the test fails again, see FAULT ISOLATION
above.
PASS Tie trunk Loop Around and Conference Test is successful. This port is
functioning properly.
1. If users are reporting troubles, examine loop connections to the port.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the
board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
between the internal ID and the port.
Table 3-492. TEST #33 Loop Around and
Conference Circuit Test — Continued
Error
Code
Te s t
Result Description/ Recommendation
Continued on next page