Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-840MMI-BD
3
MMI Synchronization Status Test (#1122 and
1123)
This test is non-destructive. To support applications involving multiple MMI circuit
packs, the appropriate MMI circuit packs must be synchronized with one
another. One such circuit pack is designated as the master sync source, which
provides the synchronization signal onto the TDM bus. The other MMI circuit
packs in the system listen to this signal.
This test monitors this synchronization state. The test fails if the MMI circuit pack
is not in sync. The test passes with auxiliary code 1100 if the MMI circuit pack is
in sync and is providing the synchronization signal for the system. The test also
passes with an auxiliary code of 1101 if the MMI circuit pack is in sync and
listening to the sync signal. MMI circuit packs do not lose the synchronization
signal unless an MMI circuit pack is either pulled out of the system or reset by
using a technician command.
Test #1122 runs when the
long
option of the
test board
command is entered,
initiating the recovery of synchronization. Test #1123 runs when the
short
option
of the
test board
command is entered, giving the status of the synchronization.
You need not necessarily run the
long
option since synchronization signal
recovery should be taking place within software running in the background. Use
the
long
option only if synchronization is not established within 5 minutes of
investigating the problem.
Table 3-365. TEST #1122/1123 MMI Synchronization Status Test
Error
Code
Te st
Result Description/Recommendation
ABORT Internal system error. This is an abnormal abort.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT A response to the test was not received from the MMI circuit pack within the
allowable time period.
1. If this result occurs repeatedly and the MMI circuit pack is idle, reset the
circuit pack using busyout board PCSS, then reset board PCSS,
followed by release board PCSS.
2. Rerun the test; if the same result occurs again, replace the MMI circuit
pack.
2012 ABORT Internal system error
2100 ABORT Could not allocate the necessary resources to run this test. This is an
abnormal abort.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page