DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-43display alarms
2
System resets, that are less severe than a reboot, rarely affect the error and alarm
logs.
NOTE:
If the error and alarm logs contain SYSTEM errors, then use the
display
initcauses
command to search for information that system could
not
log
during reset operation.
Feature Interactions
■ If the user disables the alarm origination with the
change
system-parameters maintenance
command, then the
Ack?
(Acknowledged) field on the Alarm Report is blank regardless of the true
acknowledged state of the alarm.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
display alarms
print
schedule
Report sent to printer
Command is validated and then
a scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue
and is executed at the specified
time. The information displayed
by the command is sent to the
system printer instead of the
screen.
1
Examples:
display alarms
display alarms print
display alarms schedule
1 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
cust
rcust
bcms
browse
all alarms
displayed
See below