Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-18busyout trunk
2
alarms (error type 18) are generated on each tone clock circuit pack busied out,
so that INADS can determine the state of the objects. The command,
release
tone-clock
, reactivates the specified tone/clock.
Output
The following example is a display of the
busyout tone-clock
command.
Field descriptions
busyout trunk
The
busyout trunk
command places the specified installed or uninstalled trunk
group or trunk group member in a maintenance busy state. No periodic or
scheduled tests are performed on the busied out trunk groups or trunk group
members until they are released. When the object is maintenance busy it is
deactivated (no call processing activity may include the busied object). A single
group member can be busied out by specifying the group and member number.
All members in a trunk group can be busied out by specifying the trunk group
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
busyout
tone-clock
location
Physical location (
PCC
)
Examples:
busyout tone-clock 01c
busyout tone-clock 03d
init
inads
craft
1 (one) none
Port
Tone/clock board address (cabinet-carrier)
Maintenance Name
Circuit pack name: TONE-PT, TDM-CLK, TONE-BD
Alt. name
Not applicable
Result
Test result: Pass, Abort, Fail
Error Code
Numeric code explaining why the release failed or aborted. Refer to
the detailed list of the codes by test number for each MO.
busyout tone-clock 1a SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01A TONE-PT PASS
01A TDM-CLK PASS
01A TONE-BD PASS
Command successfully completed