Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-180ATM-EI (Expansion Interface Circuit Pack)
3
ATM Board Reset (#1256)
This test is destructive. If the ATM-EI board is in the PPN or is a standby in the
EPN, the reset is done through the SAKI reset interface. If the ATM-EI is an
Expansion Arch Angel (active ATM-EI board in the EPN) a special message is
sent to the board over the EAL if the EAL is present.
Table 3-74. ATM Board Time Of Day Update (#1261)
Error
Code
Test
Result Description/ Recommendation
2031 FAIL The attempt to send the message to the ATM-EI circuit pack was not
successful.
2500 FAIL Did not send the time of day information to the board.
1. Retry the command at 1-minute intervals a maximum of 3 times.
PASS The ATM-EI circuit pack is successfully updated with system time.
1. If the status port-network command still indicates that this link is
down, it is possible that one or both of the ATM-EI circuit packs have
been busied out.
2. If the link still does not come up, reset one or both ATM-EI circuit
packs on the link.
0NO
BOARD
No board detected.
1. Resolve either wrong board (Error 125) or no board (Error 131)
issues, if applicable.
2. Check that the board is properly translated and inserted. If so, check
for hyperactivity (Error 1538). If hyperactive, use the reset board
UUCSS command.
3. Run the test again. If it fails, the NCE chip on the circuit pack may be
bad. Replace the pack and retest.
Continued on next page
Table 3-75. ATM Board Reset (#1256)
Error
Code
Test
Result Description/ Recommendation
1386 ABORT No Active EAL to the board. This error applies only if the board under
test is in EPN. Check the error logs for SYS-LINK errors against the port
network in which the ATM-EI is residing and take appropriate diagnostic
action for the SYS-LINK.
Continued on next page