Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-849MMI-PT
3
Table 3-368. TEST #1111 Resource Looparound Test
Error
Code
Te s t
Result Description/Recommendation
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Retry the command at 1-minute intervals a maximum of five times.
2. Use the status conference command to determine if there is an active
conference. If a call is active, the test cannot be run until the conference
call terminates.
1002 ABORT The system could not allocate time slots for the test. The traffic load on the
system may be very high or time slots may be out-of-service due to TDM-Bus
errors. Refer to ‘‘TDM-BUS (TDM Bus)’’
to diagnose any active TDM Bus
errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals a maximum of five times.
1003 ABORT The system could not allocate a tone detector for the test. The system is
oversized for the number of tone detectors present or some tone detectors
are out-of-service.
1. Resolve any ‘‘TTR-LEV (TTR Level)’’
errors in the Error Log.
2. Resolve any ‘‘TONE-PT (Tone Generator)’’
errors in the Error Log.
3. If neither condition exists, retry the test at 1-minute intervals a maximum
of five times.
1004 ABORT The resource has been seized by a user for a valid call. Use the status
conference command to verify that there is a conference call active.
1. If there are no conference calls, retry the command at 1-minute intervals
a maximum of five times.
2000 ABORT Response to the test was not received from the Tone Detector circuit pack
within the allowable time period.
1. If this result occurs repeatedly, reset the circuit pack, if the other ports
are not in use. Reset the circuit pack by issuing the busyout board
PCSSpp and the reset board PCSSpp commands, followed by the
release board PCSS command.
2. If this result occurs again, replace the circuit pack.
2012 ABORT Internal system error
2100 ABORT Could not allocate the necessary resources to run this test. Abnormal abort.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page