DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-90display test-schedule
2
Test Type
One of the following types of test to be performed on the trunk
group/members in this schedule:
full
(default) runs the most comprehensive test and collects all
associated measurements for each TTL type.
supv
performs a supervision test and only confirms the
presence of the test set at the far end. No measurements are
taken for this test.
no-st
runs the "full" test, but skips any self-test sequences. This
saves about 20 seconds on the type 105 test and does not
have any effect on type 100 or 102 tests.
no-rl
runs the "full" test, but skips any return loss sequences.
This saves about 20 seconds on the type 105 test and does not
have any effect on type 100 or 102 tests.
no-st/rl
runs the "full" test, but skips all self-test and return loss
sequences. This saves about 40 seconds on the type 105 test
and does not have any effect on type 100 or 102 tests.
Duration
The maximum number of hours (
1
to
24
) a schedule can remain
active. Schedules continue to run until all trunk group/members for
that particular schedule are tested or until the schedule duration is
reached. If the duration is reached before all trunk
groups/members can be tested, the schedule stops.
Trk Trp
The trunk group numbers to be tested when this schedule runs.
There is no limit to the number of times that a trunk group can
appear on any particular schedule, or to the number of different
schedules in which a trunk group can appear. Default is blank.
Bgn Mbr
The beginning member number of the trunk group to be tested;
default is
1
.
End Mbr
The ending member number of the trunk group to be tested. This
value must be greater than or equal to the value of the beginning
member field.