Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-415CONFIG (System Configuration)
3
CONFIG (System Configuration)
The System Configuration maintenance object (MO) oversees logical insertion
and removal of circuit packs in the system. When Switch Control detects that a
circuit pack is present in a port slot, it informs System Configuration and System
Configuration queries the circuit pack to determine the type and vintage of the
circuit pack. Similarly, when Switch Control detects that a circuit pack has been
removed from a port slot, it informs System Configuration.
There are no alarms or tests for System Configuration, but three types of errors
are logged to the Hardware Error Log (see below).
Hardware Error Log Entries and Test to Clear
Valu es
Notes:
a. This error indicates that a Port circuit pack in the system did not respond
to a circuit pack type inquiry. Follow the procedures outlined in (c) to
determine if there is an error.
b. This error indicates that less than 25% of Trunk Group is available.
c. This error indicates that a Port circuit pack in the system did not respond
to a vintage inquiry.
As a result of either of these errors, a Port circuit pack may be physically
inserted in a Port slot, but the system may not recognize it.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run Full Name of MO
CONFIG none none System Configuration
Error Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any none
2-117(a) 0-2 none
257(b) none
1002-1117(c) 0-2 none