Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-68ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line)
3
7
13
14
15
(cont’d.)
FAIL
(cont’d.)
1. Disconnect the terminal equipment from the circuit pack at the
cross-connect and run the test again.
2. If the test fails again, replace the circuit pack and reconnect the
terminal equipment. If the test passes the second time, then the test
results were affected by the terminal equipment connected to the port;
in this case, ignore the results of this test if all other tests pass or abort
and the station is operating properly. Failure of test 47 does not cause
an alarm. If there are failures of other tests, then investigate those
errors. User reported troubles with this port should be investigated by
using other port tests, by examining station wiring, and by examining
the station to ensure that it is correctly translated as off-premises or
on-premises.
NOTE:
If the loop around and conference circuit test fails for all ports on a
circuit pack, a -5 volt power problem is indicated.
PASS The port is able to provide an analog transmission path to the station
equipment. User-reported troubles on this port should be investigated by
using other port tests, by examining station wiring, by examining the
station, and by ensuring that the terminal is correctly translated as
off-premises or on-premises.
NOTE:
This test always passes for TN742 Analog circuit packs prior to
Vintage 6.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
dispatch to check to ensure that there is a valid board inserted.
Table 3-27. TEST #47 Loop Around and Conference Test — Continued
Error
Code
Te s t
Result Description/ Recommendation
Continued on next page