Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-57Troubleshooting Features
1
8. Set the dip (option) switches for each of the two ports to be tested on the
Tie Trunk circuit pack to “E & M mode” and “unprotected.”
9. Enter
add trunk n
command to add a new (test) trunk group. Then enter
the following information:
Group Type — tie
TAC — (use trunk access code obtained from dial plan)
Trunk Type (in/out) — wink/wink
Port — assign two of the ports from the tie trunk
Mode — E & M
Type — specify one port as t1 standard and other port as t1
compatible
Examples of the Trunk Group forms are shown in
Figure 1-13
and
Figure
1-14.
Figure 1-13. Trunk Group Form
display trunk-group 10 Page 1 of 5
TRUNK GROUP
Group Number: 10 Group Type: tie CDR Reports? y
Group Name: tr 10 COR: 1 TAC: 110
Direction: two-way Outgoing Display? n Data Restriction? n
MIS Measured? n
Dial Access? y Busy Threshold: 60 Night Service:
Queue Length: 0 Internal Alert? n Incoming Destination:
Comm Type: voice Auth Code? n
TRUNK PARAMETERS
Trunk Type (in/out): wink/wink Incoming Rotary Timeout(sec): 5
Outgoing Dial Type: tone Incoming Dial Type: tone
Disconnect Timing(msec): 500
Digit Treatment: Digits:
Used for DCS? n
ACA Assignment? n
Baud Rate: 1200 Synchronization: async Duplex: full
Incoming Dial Tone? y Maintenance Tests? y
Answer Supervision Timeout: Suppress # Outpulsing? n