DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-69ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line)
3
Station Present Test (also called Ringing
Application Test) (#48)
This test provides a burst of ringing current to the terminal equipment and
detects that current flows. This test is to ascertain whether or not terminal
equipment is connected to the port.
This test may cause some terminal equipment to ring briefly during daily
maintenance. If this ringing is disturbing the customer or the terminal equipment,
it should be disabled using the Tests field of the station administration screen.
However, on some releases of the software, this action disables Tests #6, #47,
and #35 as well as Test #48.
Table 3-28. TEST #48 Station Present Test
Error
Code
Te st
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test were not available. The port may
be busy with a valid call.
Use the display port PCSSpp to determine the station’s extension. Enter
status station extension to determine the service state of the port. If the
port is in use, it will be unavailable for certain tests. Wait until the port is idle
before retesting.
1. If the port is idle, retry the command at 1-minute intervals up to 5 times.
2. Check for phone left off-hook or for wiring problems.
1004 ABORT System resources required to run this test are not available. The port may
be busy with a valid call. Use the display port PCSSpp command to
determine the station extension. Use the status station command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. (Refer to the
"Status Commands" section in Chapter 8, "Maintenance Commands and
Trouble-Clearing Aids", for a full description of all possible states.) You
must wait until the port is idle before retesting.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page