Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-996SW-CTL (Switch Control)
3
Notes:
a. This error may not cause a Switch Control alarm if Error Type 769 is also
present since this error may actually be caused by the loss of clock
signals and not by a Switch Control failure.
b. The 257 errors are reported to the processor by the Switch Control and
indicate possible hardware problems on the Processor circuit pack. The
receipt of these errors causes Switch Control maintenance to run specific
Switch Control tests. If there really is a problem, the Switch Control tests
usually causes other errors to be logged. In the rare case where no other
errors are logged but 257 errors are occurring at a high rate (more than 10
in the last hour), the Processor circuit pack should be replaced at the
customer’s convenience.
c. If the Aux Data is less than 100, the test may have been interrupted by
LMM operations. Wait 1 minute, then test again. Retry the test a maximum
of 3 times. If the Aux Data is more than 100 or fails two out of three times
with Aux Data less than 100, the Processor circuit pack needs to be
replaced.
d. A 769 error occurs when the Switch Control reports a loss of timing signals
to the processor. When this error is present, the Switch Control is usually
not alarmed since any Switch Control test failures are really the result of
513 (c) Time of Day Clock
Test (#95)
MINOR ON test network-control a l r 3
769 (d) Any None
1025 Switch Control
Loop Around Test
(#92)
MAJOR ON test network-control a r 3
1281 (e) Any None
1537 Switch Control
Reset Test #93
MAJOR ON test network-control a l r 2
1793 (f) Any None
3329 (g) None MAJOR ON (g)
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Table 3-441. SW-CTL Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page