Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-350CLAN-BD (Control LAN Circuit Pack)
3
Aux Data:
f.
Error Type 769
: Logic error. By itself this error may be ignored, but it may
result in other error types being reported.
g.
Error Type 1293-1295
: Critical hardware or firmware error.
Error Type descriptions are as follows:
1. Attempt to clear the alarm (
reset board UUCSS
).
2. If alarm persists, replace circuit pack.
h.
Error Type 1537
: Switch removed hyperactive circuit pack that reported
threshold number of errors.
1. Attempt to clear the alarm (
reset board UUCSS
).
2. If the error recurs within 15 minutes, replace the circuit pack.
i.
Error Type 1794
: Packet bus transmit buffers have overflowed..
1. Attempt to clear the alarm (
reset board UUCSS
).
2. If the error recurs within 15 minutes, replace the circuit pack.
j.
Error Type 1798
: Unable to write translation RAM.
1. Attempt to clear alarm (
reset board UUCSS
).
2. If alarm recurs within 15 minutes, replace the circuit pack.
k.
Error Type 2049
: Packet Interface Test (#598) failed.
1. Attempt to clear the alarm (
test board UUCSS l r 3
).
2. If alarm does not clear, reset the circuit pack (
reset board UUCSS
).
4352 External RAM error
4353 Internal RAM error
4355 ROM Checksum error
4356 Angel Message Corruption error
4357 Instruction set error
If the switch detects: Then the switch:
1 error, Resets circuit pack.
3 errors in 15 minutes, Raises MINOR alarm.
1293 Insane onboard processor
1294 Onboard translation RAM error
1295 (Aux 3) RSCL link down
(Aux 0) RSCL keep alive failure