Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-731ISDN-SGR (ISDN-PRI Signaling Group)
3
Table 3-308. TEST #647 Layer 2 Status Query Test
Error
Code
Te st
Result Description/ Recommendation
1132 ABORT Internal system error
The port location for the primary ISDN-PRI D-channel is not known. This
condition should not be possible since an administered DS1 circuit pack
must be specified when a Signaling Group is administered:
1. Retry the command at 1-minute intervals a maximum of 5 times.
1134 ABORT Internal system error
The associated DS1 circuit pack is not administered. This condition should
not be possible since an administered DS1 circuit pack must be specified
when a Signaling Group is administered.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1 FAIL Layer 2 of the primary signaling channel is down:
1. Examine the results of the Primary Signaling Link Hardware Test (#636)
and follow recommendations provided there.
2. If test #636 passes, the Layer 2 Query test may still fail if the Signaling
Channel at the far end has not been administered correctly or if it has
been busied out. Verify that the Primary Signaling Channel (D-channel)
at the far end has been administered correctly. Verify that the DS1 port
used for the Primary D-channel has not been busied out at the far end.
2 FAIL Layer 2 of the secondary signaling channel is down.
1. Examine the results of Secondary Signaling Link Hardware Test (#639)
and follow recommendations provided there.
2. If tests #639 passes, the Layer 2 Query test may still fail if the Signaling
Channel at the far end has not been administered correctly or if the
Signaling Channel has been busied out. Verify that the Secondary
Signaling Channel (D-channel) at the far end has been administered
correctly. Verify that the DS1 port used for the Secondary D-channel
has not been busied out at the far end.
Continued on next page