DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-808MEDPROPT (TN802 MED PRO DSP PORT)
3
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order they are presented in Table 3-350. By clearing error
codes associated with the
DSP Capacity Query Test,
for example, you may also
clear errors generated from the other test in the testing sequence.
DSP Capacity Query Test (#1382)
This test is non-destructive
This test polls the circuit pack for the number of failed DSPs. If all DSPs are
functional, the test passes and the board is operating at maximum capacity. If
any DSPs have failed, the test fails and reports the number of failed DSPs.
A failure of 3 or fewer DSPs does not result in an alarm. A failure of more than 3
up to 8 DSPs results in a warning alarm. A failure of more than 8 DSPs results in a
minor alarm. In all cases, except all DSPs failing, the MEDPROPT continues to
provide reduced capacity.
Table 3-350. System Technician-Demanded Tests
Order of Investigation
Short
Tes t
Sequence
Long Test
Sequence
Reset
Board
Sequence
test
ds1-loop D/ND
1
1. D = Destructive; ND = Nondestructive
DSP Capacity Query (#1382) X X ND
TDM NIC Looparound Test (#1380) X X ND
Continued on next page
Table 3-351. DSP Capacity Query Test (#1382)
Error
Code
Te s t
Result Description/ Recommendation
2000 ABORT Response to the test was not received within the allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this test.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 3 times.
Continued on next page