DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1141TONE-PT (Tone Generator)
3
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the following tables when
inspecting errors in the system. By clearing error codes associated with the
SAKI
Sanity Test
, for example, you may also clear errors generated from other tests in
the testing sequence.
Use the
list configuration control
command to find the Tone-Clock Circuit Pack
Code of the system. Then look for the Short and Long Test Sequences according
to the Tone-Clock Circuit Pack Code.
For a system with a TN2182 Tone-Clock Circuit Pack
:
Notes:
a. Refer to XXX-BD (Common Port Circuit Pack) Maintenance documentation
for descriptions of these tests.
b. Refer to TONE-BD (Tone-Clock Circuit Pack) section for descriptions of
these tests.
c. Refer to TDM-CLK (TDM Bus Clock) section for descriptions of these tests.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
SAKI Reset Test (#53) (a) X D
Clock Health Test (#46) (b) X X ND
Control Channel Loop Around Test (#52) (a) X X ND
Tone Generator Crosstalk Test (#90) X ND
Tone Generator Transmission Test (#40) X X ND
Tone Generator Audit/Update Test (#41) X X ND
TDM Bus Clock Circuit Status Inquiry Test (#148) (c) X X ND
TDM Bus Clock Slip Inquiry Test (#149)(e)(c) X X ND
TDM Bus Clock PPM Inquiry Test (#150) (c) X X ND
TDM Bus Clock Parameter Update Test (#151) (c) X X
Board Type Check Test (#574) (c) X X
Standby Reference Health Check Test (#651) (c) X