DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1142TONE-PT (Tone Generator)
3
Tone Generator Transmission Test (#40)
The purpose of this test is to verify that the tone generation hardware on the
tone-clock circuit pack is capable of generating a subset of system tones and a
set of test tones. This test does not verify all system tones the tone generator
produces during normal system operation.
The test is performed in two parts. For the first part, the Tone Generator is told to
generate the touch-tone digits. The digits are received and checked by a Tone
Detector touch-tone detector. If any of the digits fail, the test is repeated using a
touch-tone detector in another Tone Detector circuit pack.
For the second part, the Tone Generator is told to generate call progress tones
that are detected and identified by a tone detector. These tones are:
440 Hz
2225 Hz
Digital Count
The tone generator is then told to generate a sequence of test tones whose
output levels are measured by a tone detector. These tones are:
404 Hz at 0 dB
1004 Hz at -16 dB
1004 Hz at 0 dB
2804 Hz at 0 dB
A Tone Detector general purpose tone detector listens for the tones and
measures the quality of the tone. If any of the measured values are not within
limits, the test is repeated using a general purpose tone detector in a different
Tone Detector circuit pack. If the values are still out of the limits, the test will fail.
For all the failure cases of Test #40, do the following:
1. Check that all Tone Detector circuit packs have the same companding
mode as that administered for the system. Correct the situation if there is a
mismatch.
2. Run the long test sequence:
test tone-clock PC long repeat 1
.
3. If the problem persists, replace the Tone-Clock circuit pack by following
the steps outlined in the ‘‘How to Replace a Tone-Clock Circuit Pack’’
section.