Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-6busyout data-module
2
busyout data-module
This command puts the specified data module in a maintenance busy state, even
uninstalled data modules. No periodic or scheduled tests is performed on the
busied out data module or data channel until it is released and no call
processing can be executed on the data modules or over the data channels.
Warning alarms are generated (error type 18) on each maintenance object
busied out, so that INADS can access the state of the objects. The
release data
module
command returns the specified data module (or data channel) to
operation.
On a system with the duplication option, a busyout of a Network Control Data
Channel (DATA-CHL) or a Processor Interface Port Data Channels (PI-PT) are
preserved across SPE interchanges. The data channel extension must be
released before the data channel can be brought back into service.
Output
The following example shows the output from the
busyout data-module 300
command.
Result
Test result: Pass, Abort, or Fail
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
busyout
data-module
extension
Extension number (per
dial-plan)
Example:
busyout data-module 31300
init
inads
craft
nms
None None
busyout data-module 300 SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01C1103 DIG-LINE 300 PASS
Command successfully completed