DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-146ATM-EI (Expansion Interface Circuit Pack)
3
3. Enter
add atm pnc
n
(connection number), and administer the circuit
pack location and ATM address.
4. Enter
change system-parameters duplication
and change the
Enable
Operation of PNC Duplication
field to
y
.
Removing ATM PNC connections
Standard Reliability
NOTE:
Standard Reliability systems are
not
equipped with PNC duplication.
1. Enter
busyout atm-pnc
n
(connection number)
2. Enter
remove atm-pnc
n
(connection number)
Critical Reliability
1. Enter
status pnc
and ensure that the A-PNC is active. If it is not active,
request a PNC interchange using the
reset pnc interchange
command.
2. Enter
busyout pnc-standby
.
3. Enter
change system-parameters duplication
and change the
Enable
Operation of PNC Duplication
field to
n
.
4. Enter
busyout atm-pnc
n
(port network number).
5. Enter
remove atm pnc
n
(port network number) to remove both ATM-EI
boards, or enter
change atm pnc
to remove the B-side ATM-EI board.
6. Enter
change system-parameters duplication
and change the
Enable
Operation of PNC Duplication
field to
y
.
Changing circuit pack location or ATM address
Standard Reliability
NOTE:
Standard Reliability systems are
not
equipped with PNC duplication.
1. Remove the ATM PNC connection (see ‘‘Removing ATM PNC
connections’’ above).
2. Add an ATM PNC connection (see ‘‘Adding ATM PNC connections’’
above).
A-side ATM-EI — Critical Reliability
1. Remove the ATM PNC connection (see ‘‘Removing ATM PNC
connections’’ above).