DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-259AXA12-RS/ADX8D-RS/AXD12-RS (AUDIX Reserve Slots)
3
AXA12-RS/ADX8D-RS/AXD12-RS
(AUDIX Reserve Slots)
There are no tests associated with these MOs. Both the
test board
and
busy out
board
commands abort when either is attempted on a reserved slot. An error
message indicates that the slot is associated with the circuit pack that the TN568
is emulating, but the requested operation is not valid. If there are errors logged
against these maintenance objects, see XXX-BD.
The TN568 circuit pack connects to the switch through a single slot in the
backplane; however, the number of slots physically occupied by the circuit pack
is supplied by the board when inserted. The TN568 is 2 slots wide: the functional
slot and a reserve slot. The reserve (blank) slot to the left of the functional slot is a
place holder on the switch and has no interaction with the switch.
These MOs are place holders for the extra slot needed for the DEFINITY AUDIX
board. Each instance of these MOs represents a reserve slot associated with the
respective circuit pack mode in which the TN568 (DEFINITY AUDIX) is working.
They are used for embedded AUDIX and emulation of respective port types.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to
Run Full Name of MO
AXA12-RS NONE NONE TN568 12-port analog
reserve slot
ADX8D-RS NONE NONE TN568 8-port digital reserve
slot
AXD12-RS NONE NONE TN568 12-port digital
reserve slot