DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-649ETH-PT (Control LAN Ethernet)
3
TCP/IP PING Test (#1281)
This non-destructive test fails if all the endpoints fail to respond. Use this test to
check the circuitry in the data path for a peer-to-peer IP layer connection.
Table 3-269. TEST #1281 TCP/IP PING Test
Error
Code
Test
Result Description/ Recommendation
1, 2,
11
ABORT Internal error
1. Retry the command at 1-minute intervals a maximum of 3 times.
2. If the problem persists, escalate the problem.
7 ABORT Destination unreachable.
1. Verify that there is a destination to ping in the routing table (list ip-route
and look for destinations reachable through this ethernet port).
2. If there are no reachable destinations from this port (i.e., no routes
administered on ethernet), administer a route and retry.
3. Escalate if the problem persists.
1005 ABORT Incorrect test configuration.
1. Verify Ethernet link is in service (status port UUCSSpp or status link
n).
2. Verify that Ethernet link is enabled (status port UUCSSpp or status
link
n
or display data-module).
3. Verify routing table has reachable destinations.
4. Repeat the test.
5. If problem persists while the Ethernet link is in service and enabled,
escalate the problem.
1124 ABORT Ethernet link is not enabled.
1. Verify that the Ethernet link is enabled (status port UUCSSpp, status
link
n
, or display data-module).
2. If the link is not enabled, enable the link (change data-module).
3. Repeat the test.
4. Escalate if the problem persists.
1125 ABORT Ethernet link not in service.
1. Verify Ethernet link is in service (status port UUCSSpp or status link
n).
2. If the link is not in service, release the link using (release link n or
release port UUCSSpp).
3. Repeat the test.
4. Escalate if the problem persists.
Continued on next page