DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-184release journal-printer
2
Feature Interactions
Specific component maintenance performed on a link sometimes conflicts with
link maintenance, itself (busied out objects create link setup failure). Frequent
link re-setup attempts may delay faulty component recovery. For best results,
technicians should use busyout to disable attempted link re-setup.
Output
The following example shows the output from the
release journal-printer
wakeup-log
command.
Field descriptions
Port
Port address (cabinet-carrier-slot-circuit) of busied out or
released maintenance object. (wakeup log = 0; pms log = 1)
Maintenance Name
Type of busied out or released maintenance object.
Alt. Name
Not applicable.
Result
Test result: Pass, Abort, or Fail.
Error Code
System-generated description of a command failure.
release journal-printer wakeup-log
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
0 JRNL-LINK PASS
Command successfully completed