DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-335test eda-external-device-alrm
2
Output
The following example shows the output for the
test ds1-loop 1c07
command,
and assumes that the board in cabinet 1, carrier c, slot 7 is a TN767E DS1 board.
The responses display on a test-by-test basis with one line of data for each test
result.
Field descriptions
test eda-external-device-alrm
This command performs a hardware diagnostic test on all or specific port’s
administered external device alarms. The test PASSES if the external device
is
not
reporting an external device alarm and FAILS if the external device
is
reporting an external device alarm. If you are entering a specific port, it must
already be administered as an external device alarm port on a maintenance or
an analog line port carrier board.
Port
Port address (cabinet-carrier-slot-circuit)
Maintenance
Name
The name of maintenance object
Alt. Name
The alternate means of identifying the maintenance object.
Test No
The test being executed
Result
Test result: Pass, Abort, Fail, No Board, Disabled, or Extra Bd
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test ds1-loop 01C07 ds1/csu-loopback-tests
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C07 DS1-BD 1209 PASS
01C07 DS1-BD 1210 PASS
01C07 DS1-BD 1211 PASS
Command Successfully Completed