DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-938PPP-PT (Control LAN Packet/Port)
3
Table 3-404. TEST #1286 Session Status Test
Error
Code
Test
Result Description/ Recommendation
1124 ABORT ppp link is not enabled.
1. Verify that the ppp link is enabled (status port UUCSSpp, status link
n
,
or display data-module).
2. If the link is not enabled, enable the link (change data-module).
3. Repeat the test.
4. Escalate if the problem persists.
1125 ABORT PPP link not in service.
1. Verify whether PPP link is in service (status port UUCSSpp or status
link n).
2. If the PPP link is not in service, release the link (release link n or release
port UUCSSpp).
3. Repeat the test.
4. Escalate if the problem persists.
2000 ABORT Did not receive circuit pack test response within the allowable time period.
1. If the problem persists, reset the circuit pack (busyout port UUCSSpp,
reset board UUCSS, and release board UUCSS).
2. If the problem persists, replace the circuit pack.
2100 ABORT Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
2500 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
1 FAIL System software indicates at least one PPP link session is down (SOME UP).
1. Isolate downed sessions (status port UUCSSpp or status link n).
Follow actions based on session information.
Continued on next page