DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-630E-DIG-STA (Emulated Digital Line)
3
E-DIG-STA (Emulated Digital Line)
There are 4 tests in the Emulated Digital Line station maintenance test sequence
and only one test path in the test sequence. Once the test sequence is started,
all tests in the test sequence are executed.
E-DIG-ST maintenance monitors and tests ports on the TN800 MAPD circuit pack
and the hardware connected to those ports for lines administered as a digital
station. These include stations with an emulated digital voice terminal and
stations with an emulated digital voice terminal and a linked data module.
Stand-alone data modules and data adaptors in stand-alone mode are not
supported by the TN800 circuit pack. Circuit pack maintenance is covered by
E-DIG-BD.
Hardware Error Log Entries and
Test to Clear Values
MO Name (in
Alarm Log) Alarm Level
Initial Command to
Run
1
1. Where P is the port network number (1 for PPN); C is the carrier designation (for
example, A, B, or C); and SS is the address of the slot in the carrier where the circuit
pack is located (for example, 01, 02, ...).
Full Name of MO
E-DIG-STA MINOR test port PCSSpp l Emulated Digital St.
E-DIG-STA WARNING test port PCSSpp sh Emulated Digital St.
Table 3-259. Digital Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
18 (a) 0 busyout port PCSSpp WNG OFF rel port PCSSpp
130 (b) None WNG ON test port PCSSpp sh
1793 (c) Voice and Control Local
Loop Test (#13)
MIN/
WNG
2
ON test port PCSSpp l r 3
2049 (d) NPE Crosstalk Test (#9) MIN/
WNG
2
ON test port PCSSpp l r 3
2305 (e) 32770 None
Continued on next page