Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-975PROC-SAN (Process Sanity Audits)
3
PROC-SAN (Process Sanity Audits)
The Process Sanity Audits MO is responsible for monitoring the sanity of software
processes in the system. If the Process Sanity Audits MO detects that a process
has gone insane (does not respond to a sanity message within an allotted time
period), the process is restarted. If the Process Sanity Audits MO detects that
multiple processes (or a single key process) do not respond to sanity messages
within an allotted time period, a system recovery action is initiated.
The Process Sanity Audits MO has no alarms and no tests. Certain errors are
logged to the Hardware Error Log for information purposes only.
Error Log Entries and Test to Clear Values
Notes:
a. These errors indicate that a system recovery action has been taken
because one or more software processes failed to respond to a sanity
audit in a timely fashion. As a result of the recovery action, the system may
have temporarily suspended service for a period of time surrounding the
error.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run Full Name of MO
PROC-SAN none none Process Sanity Audits
Table 3-429. Process Sanity Audits Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Look for other errors of the same type and deal with them accordingly.
0 Any Any Any none
10 (a) 0 none none none none
204 (a) any none none none none