DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-353test led
2
technician needs to be able to disable the attempted re-setup of a link. Use of
the busyout command causes the link to be torn down. If the link is already down,
the busyout command will stop periodic re-setup trys on the link.
Output
The following example shows the output for the
test journal-printer pms-log
command. The responses display on a test-by-test basis with one line of data for
each test result.
Field descriptions
test led
This command performs a test on all the LEDs in a specified cabinet. Once the
cabinet is validated and the range of circuit packs determined, the
test led
command turns on all LEDs on the circuit packs contained in each carrier until all
affected carriers are lit. Once all the LEDs are on, there is a 2-second pause, and
then all the LEDs are turned off in the same order. Once all of the repeat cycles
are completed, all affected LEDs are restored to the current status.
Port
Not applicable (always blank)
Maintenance
Name
The name of maintenance object being tested:
PMS-PRINT for testing the pms-log printer link
JNL-PRNT for testing the wakeup-log printer link
Alt. Name
Not applicable (always blank)
Test No
The test being executed
Result
Test result: Pass, Abort, Fail, Disabled
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test journal-printer pms-log short
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
JRNL-LINK 215 PASS
Command Successfully Completed