DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-252ATM-TRK (Circuit Emulation Service Circuit Pack)
3
1144 ABORT Major alarm on the PPN packet bus
1. Run display alarms, and perform the repairs associated with PKT-BUS.
2. Run display errors, and perform the repairs associated with PKT-BUS.
3. Retry the command.
1394 ABORT ATM-TRK circuit pack out of service
1. Run ATM Board Reset Test #1256.
2000 ABORT Request timed out.
1. Retry the command up to 3 times at 1-minute intervals.
2060 ABORT Packet-bus link has failed.
1. Retry the command up to 3 times at 1-minute intervals.
2. If the test continues to abort, run display errors, and perform the repairs
associated with PKT-INT errors.
2100 ABORT Could not allocate the necessary system resources to run this test.
2500 ABORT Internal system error
1. Retry the command up to 3 times at 1-minute intervals.
1 FAIL Test tone not detected over the looparound; packet-path test aborted.
1. Test the active tone clock on the port network, and verify that a tone is
reaching the ATM-TRK circuit pack. If not, correct the condition.
2. Run test board UUCSS long.
3. If the test continues to fail, replace the ATM-TRK circuit pack or
transceiver.
4. Rerun test board UUCSS long.
2 FAIL TN1655 Packet Interface circuit pack could not detect the correct data
packet.
1. Test the TN1655 Packet Interface circuit pack to verify that it is functioning
properly. If not, correct the condition.
2. Run display errors, and perform the repairs associated with DS1
CONV-BD errors, if applicable.
3. Run display alarms, and perform the repairs associated with DS1
CONV-BD alarms, if applicable.
4. Run test board UUCSS long.
5. If this test continues to fail, replace the ATM-TRK circuit pack.
6. Run test board UUCSS long.
Table 3-111. ATM Board Framer Looparound Test (#1260) — Continued
Error
Code
Tes t
Result Description/ Recommendation
Continued on next page