DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-32change system-parameters maintenance
2
Test Type 102
Test Type 102 tests far end to near end loss by sending:
9 seconds of 1004 Hz tone at 0 dB
1 second of quiet
This cycle is repeated until disconnect; disconnect is forced
after 24 hours.
Test Type 105
Test Type 105 tests 2-way loss, gain slope, and C-message and
C-notch noise by sending:
nine seconds of 1004 Hz at -16 dB
one second of quiet
nine seconds of 404 Hz at -16 dB
one second of quiet
nine seconds of 2804 Hz at -16 dB
30 seconds of quiet
one-half second of Test Progress Tone (2225 Hz)
approximately five seconds of quiet
forced disconnect
ISDN Maintenance
ISDN-PRI Test
Call Extension
This field indicates the extension used by far-end ISDN nodes to
place calls to the system, for testing ISDN-PRI trunks between
the far-end and the system.
ISDN-BRI Service
SPID
This field shows if the link associates with the Service SPID. If the
link is associated with the Service SPID. This number is the test
SPID (0 – 99999) (under BRI-SET MO). Otherwise, this field is
blank. Service SPID is a feature used by the system technician to
check building wiring between the switch and the BRI endpoint.
DS1 Maintenance
DSO Loop-Around
Test Call
Extension
The extension used to set up a DSO loop around connection for
testing non-ISDN DS1 trunks. The DSO Loop-Around Test Call
feature is used primarily for testing DSO channels associated
with non ISDN-PRI trunks. The loop-around is activated by dialing
the test extension number; multiple DSO Loop-Around
connections can be established by placing multiple calls to the
loop-around extension.