DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-266BRI-BD/LGATE-BD (ISDN-BRI Line Circuit Pack)
3
Table 3-116. TEST #595 LANBIC Receive Parity Error Counter Test
Error
Code
Te s t
Result Description/ Recommendation
2000 ABORT Response to the test was not received from the circuit pack within the
allowable time period.
1. If the test aborts repeatedly a maximum of 5 times, reset the circuit
pack via the busyout board PCSS and reset board PCSS
commands.
2. If the test aborts again, replace the circuit pack.
2100 ABORT Could not allocate the necessary system resources to run this test.
2012 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1-10 FAIL The circuit pack is still detecting errors of this type. The error code
indicates the value of the on-board error counter.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, verify the validity of the Packet Bus. Run the
Packet Bus maintenance test with the test pkt P long command.
3. If the Packet Bus test passes, check the validity of the circuit pack.
Execute a test that involves data transmission onto the Packet Bus. For
example, the BRI may use the connectivity tests of the port-level
maintenance object (BRI-PORT) by executing the test port PCSSpp
command. Refer to the repair procedures for the executed test if it
fails. Otherwise, proceed to the next step.
4. Other circuit packs on the Packet Bus may be the cause of the parity
error. Use the display errors command to check the Error Log for
other circuit packs that are alarmed. If any alarms are present for the
other circuit packs, retire those alarms also. Then, rerun the LANBIC
Receive Parity Error Counter Test (#595) on this circuit pack.
PASS No errors detected by circuit pack.
Continued on next page