DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-326test card-mem
2
!
WARNING:
Since the “clear long” option clears all counters if tests pass, it is possible
for firmware counters to be cleared even when a problem exists. In some
cases customer service might degrade since calls may be routed over
defective equipment
.
Feature Interactions
The
test card-mem long
command invokes the Memory Card Erase/Write/Read
Test. This means that the
save translation
and
save announcement
commands
are rejected while the write-to-memory-card operation is active. This test also
invokes the Memory Card Capacity Test which determines whether the memory
card is more than 98% full. This test is also invoked after the
save translation
command.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test card-mem
location
short
long
repeat
number
clear
schedule
Carrier location where memory
card resides: (
a
)
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive test series
(includes a destructive test)
How many times each test in the
sequence is repeated (1-100)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.
1
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue and
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.
2
Examples:
test card-mem
test card-mem a l
test card-mem b sh r 2
test card-mem a sch
test card-mem a c
1 If no alarms are registered against the maintenance object then the test sequence is run only once. The
long clear
option forces a clear of all alarms if no errors are encountered during testing. The
short clear
option only clears
alarms pertinent to tests in the short sequence. SEE WARNING BELOW.
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
Test
sequence
= short;
repeat = 1
See below