DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-128ATM-BCH (ATM B-Channel Trunk)
3
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1: the two ends of the ATM trunk do not agree on the ISDN call
state. Possible causes:
Received a DISConnect or RELease COMplete message with
cause value 52 (outgoing calls barred)
Received a DISConnect or RELease COMplete message with
cause value 54 (incoming calls barred)
Outgoing call renegotiated by the far end to another B-channel in
the absence of SETUP message glare
Near end attempted a call on a B-channel that the far end has
marked OOS
When running the Short Test Sequence, pay close attention to the results
of the Call State Audit Test (#257).
Table 3-51. ATM-BCH Error Log entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port UUCSSppp
1(a
) Any None test port UUCSSppp
18 0 busyout trunk
grp/mbr
release trunk grp/mbr
129 (b
) None WNG OFF test port UUCSSppp
130 (c
) test port UUCSSppp
257(d
) Any Service State Audit (Test
#256)
test port UUCSSppp
513(e
) Any None WNG OFF test port UUCSSppp
769(f
) Any Service State Audit (Test
#256)
test port UUCSSppp
1793(g
) Any None test port UUCSSppp
3073(h
) Any Service State Audit (#256) test port UUCSSppp
3585(i
) Any None none
3841(j
) Any None WNG OFF none
Continued on next page