DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-234status card-mem
2
status card-mem
Memory cards are portable, compact memory cards that contain banks of flash
EPROM chips. Non-volatile memory cards are eraseable and randomly
programmed with user data. Main memory stores system software in its “flash”
section. Memory cards that save translations do not contain copies of the system
software. During system reboot or system power down conditions, in-core system
maintenance hardware error logs temporarily save in memory cards before the
ASAI 0-126 Hyperactive ignore ignore Link has sent too many messages
per unit time.
BRI Signaling suspends. System
timeouts in 60 seconds and
attempts reactivate the link. If links
remain in this state while no activity
occurs at BRI endpoints:
1. Ensure that SPID switch
administration and endpoints
are consistent. Verify repairs by
executing the status bri-port
PCSSpp command. Determine
that the L2 state of the signaling
link is L3-Established.
2. Replace the endpoint. Verify
repairs by executing the status
bri-port PCSSpp command.
Determine that the L2 state of
the signaling link is
L3-Established.
ASAI 0-126 L3-Restarting ext The switch sends a Restart
message to the adjunct but has not
received a Restart Acknowledgment
message from the adjunct.
ASAI 0-126 L3-Restarted ext After receiving a Restart
Acknowledgment message, the
switch sends a Heartbeat message
to the adjunct and awaits a
response.
ASAI 0-126 L3-Established ext Normal state for ASAI adjunct.
Table 2-3. Status BRI-Port Command Interpretation — Continued
Endpoint
Types
TEI
Range Layer 2 State
Voi ce
Extension
Service
SPID Description / Recommendation
Continued on next page