DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-346test inads-link
2
Field descriptions
The following example shows the output for the
test hardware-group system
with the
background
option selected.
test inads-link
This command attempts to make a call over the inads port on the maintenance
board to verify the INADS alarm notification process. In the default settings, the
system test the link to the first OSS telephone number. If there is an alarm
pending to be reported or the call is in progress or up, then the test aborts. If the
alarm origination to the OSS telephone number to be tested is disabled, then the
test generates an informative error and the test continues. The test waits 2
minutes before dialing the call to allow the remote maintenance technician to
logoff, thus freeing the line. A
local
SAT user entering the
test inads-link
command does not need to log off for the system to place the call, but the
two-minute delay still exists.
Once the call is answered by INADS, the system sends a message with a test
alarm type. INADS acknowledges receipt of the message and creates a trouble
ticket. The trouble ticket is closed immediately and has a “INADS LINK TEST”
message entered in the description field. If an alarm is raised while the test call is
up, the system does not send an alarm message over the existing link. The
Port
Port address (cabinet-carrier-slot-circuit)
Maintenance
Name
The name of maintenance object
Alt. Name
Alternate way to identify maintenance objects.
If the Object is The field contains
station extension
trunk
xxx/yyy
(where
xxx
= trunk group number
and
yyy
= member number)
private CO line
P/xxx
(where
xxx
= private CO line group
number)
Test No.
The test being executed
Result
Test result: No Board, Extra Bd, Disabled, or Skipped
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test hardware-group system
Command started in background mode