Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-428DATA-CHL (Data Channel)
3
Error Log Entries and Test to Clear Values
Notes:
a. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
System Technician-Demanded Tests: Descriptions
and Error Codes
There are two system technician test commands that include the Data Channels
(DATA-CHLs). The
test data-module <ext> [short | long]
command tests the
single DATA-CHL that has the extension specified by <ext>. The
test
network-control [short | long]
command tests each administered DATA-CHL
that resides on the Processor circuit pack in the specified carrier.
Always investigate tests in the order presented in the following tables when
inspecting errors in the system. By clearing error codes associated with the
Data
Channel Reset Test,
for example, you may also clear errors generated from other
tests in the testing sequence.
Table 3-183. Data Channel Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
(a)
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test data-module <ext> sh r 1
1 Any Local Loop Back Test
(#111)
MINOR ON test data-module <ext> sh r 3
18 0 busyout data-module
<ext>
WARNING OFF release data-module <ext>
130 None WARNING ON test data-module <ext> sh
257 Any Remote Maintenance
Loop Around Test
(#109)
MINOR ON test data-module <ext> sh r 5
513 Any Crosstalk Test (#110) MINOR ON test data-module <ext> sh r 3
769 Any Dual Port RAM Test
(#108)
MINOR ON test data-module <ext> l r 3