Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-899PKT-INT (Packet Interface)
3
Error Log Entries and Test to Clear Values
1 S is the instance of the Packet Interface (1 or 2).
2 Indicates that an alarm was raised but an associated error was not entered into the hardware error log
due to a momentary overload condition caused by a burst of hardware or software error reports. Run the
long test sequence. Refer to the appropriate test descriptions for any failures and follow the
recommended procedures.
3 The I/O Processor or Packet Interface instance can only be reset if it has been taken out of service by
background maintenance software.
4 The error type or test applies only to Packet Interface 2, i.e., the Packet Interface instance that uses the
Packet Bus.
Table 3-387. Packet Interface Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
1
0
2
0 Any Any ON test packet-interface 1AS r 2
1 (a) Any None MAJOR ON reset io-processor
3
10 (b) 0 None
23 (c) 0 None MAJOR OFF
50 (d) 0 None
100 (e) 0 None
217 (g) 0 None WARNING OFF
257 (f) Any None MAJOR ON reset io-processor
3
267 (g) 0 None WARNING OFF
513 (h) Any None MAJOR ON reset io-processor
3
769
4
(i) Any Mtce Looparound Test
(#886)
4
MAJOR ON test packet-interface 1AS r 3
1025 (j) Any Private Looparound
Test (#885)
MAJOR ON reset packet-interface 1AS
3
1026 (j) Any None MAJOR ON reset packet-interface 1AS
3
1281
4
(k) Any None MAJOR ON reset packet-interface 1AS
3
1537 (l) Any Memory Checksum
Test (#884)
MINOR ON test packet-interface 1AS r 2
1793 (m) Any Memory Checksum
Test (#884)
MINOR ON test packet-interface 1AS r 2
2049
4
{n} Any None WARNING ON test packet-interface 1AS r 25
2305
4
(o) Any None test packet-interface 1AS r 2
3074 (p)
3073
3072
Any Mtce Looparound Test
(#886)
4
WARNING OFF test packet-interface 1AS s r 2
3329 (q) Any None WARNING OFF reset packet-interface 1AS
3
3585
4
(r) Any None WARNING OFF reset packet-interface 1AS
3
3841
4
(s) Any None MAJOR OFF reset packet-interface 1AS
3