2-118list measurements clan ethernet
2
high Cyclic Redundancy Check (CRC—detects and corrects errors on
every frame) errors could suggest that
the LAN connection may be “noisy”
a wire connection is loose
a wire is frayed or broken.
The 24-hour history gives the ability to look back at these measures if the trouble
cleared.
The data is collected at 15-minute intervals over 24 hours for the Cyclic
Redundancy Check (CRC) and collisions for ethernet connections. If the data
cannot be retrieved for the 15-minute interval,
N/A
displays in the field. The delta
(the change from the last inquiry) and the total are provided for each error count.
After the occurrence of “N/A” (not available), the delta equals the total.
The primary use of this command is to quickly and unambiguously determine if
the fault lies within the Lucent-provided equipment or if the fault is with the LAN
or LAN administration to which the DEFINITY ECS switch is connected.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
list
measurements
clan
ethernet
UUCss
print
schedule
Designates ethernet
connection
Cabinet-carrier-slot
address of the C-LAN
circuit pack
Report sent to printer
Command is validated
and then a scheduling
form displays to
schedule execution of
the command. The
command is then
placed in the command
queue and is executed
at the specified time.
The information
displayed by the
command is sent to the
system printer instead
of the screen.
1
Examples:
list measurements
clan ethernet 1A05
list measurements
clan ethernet 1A05
print
1 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
customer