DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-294status processor-channel
2
status processor-channel
This command displays the status of the specified processor channel and the
values of its various counters. A processor channel is 1 of 64 logical channels
associated with an SCI link. Each processor channel terminates in the switch
processing element with a session.
Service State
Service state of the B-channels:
in-service/active, in-service/idle, out-of-service-NE,
out-of-service-FE, maint-NE/active, maint-FE/active, maint-NE/idle,
and maint-FE/idle.
NE (Near End) and FE (Far End) refer to which “end” of the
B-channel has placed the facility in the current state. NE refers to
the switch and FE refers to the PRI terminal adapter (or any device
that terminates the D-channel signaling on the facility).
Test In Progress
Whether or not there is any current maintenance testing on the
port.
Connected Port
Connected port location (cabinet-carrier-slot-circuit) for each of
the B-channels active on a call.
Action/
Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
status
processor-
channel
channel
number
print
Processor channel number (1-64).
Report sent to printer
Examples:
status processor-channel 1
status processor-channel 10
status processor-channel 64
status processor-channel 64 print
init
inads
craft
cust
rcust
bcms
browse
none none