DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-220status audits
2
The date and time that the audit first detected a problem (only for
cumulative)
The time of the most recent error detected by the audit (only for
cumulative)
Audit data information cumulates from the last reboot or the last
clear audits
cumulative
command, and for peak hours since the last reboot or the last
clear
audits peak-hour
or
clear audits cumulative
commands.
NOTE:
Single process restarts, warm starts, cold 2 restarts, cold 1 restarts, or
processor interchanges do not clear this data.
Audits can execute directly using the
test MO
command. For example,
test MO l
8192 p 512 t 0
executes the Station Connections Audits, audit lnames and
numbers (pnames) included in the Table Of Audits. When the “test MO”
command executes an audit, report results display on the screen. In general,
errors discovered from a demand tests are not logged in the error logs. To be
consistent with other error logging, and to avoid confusion, errors that are
discovered from a demand test that executes an audit are not displayed.
The screen does not automatically update, but reflects the system at the time of
the request.
Action/
Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
status audits
peak-hour
cumulative
print
schedule
data collected since the last reboot
or since the last execution of the
clear audits cumulative
command.
Data for the peak hour since the
last reboot or since the last
execution of the
clear audits
cumulative
or
clear audits
peak-hour
command.
Report sent to printer
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue and
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.
1
1 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
none see below