Maintenance Objects
3-97ANN-BD (Announcement Circuit Pack)
3
!
WARNING:
All alarms are upgraded to MAJOR when the BASE Tone Generator is set to
12 (France).
Notes:
a. Error Type 1
This error indicates the circuit pack totally stopped
functioning or it was physically removed from the system.
NOTE:
The alarm is logged about 11 minutes after the circuit pack has been
removed and/or SAKI Test (#53) fails.
If the circuit pack is not in the system, insert a circuit pack (in the same
slot as the error indicates) to resolve this error. Or, if the circuit pack is in
the system and the red LED is on, follow the instructions for "Red (alarm)"
in the "Control and Port Circuit Pack Status LEDs" section in Chapter 7,
"LED Interpretation".
NOTE:
The alarm is logged about 11 minutes after the circuit pack has been
removed and/or SAKI Test (#53) fails.
!
WARNING:
Reseating and/or replacing the circuit pack results in loss of
integrated announcements (TN750/B only). See ‘‘General Notes’’
near the beginning of this Maintenance procedure.
17699
(m)
In-line Error
3840 (n) Any None
3999 (o) Any None
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
Table 3-36. Announcement Circuit Pack Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm Level (See
WARN I NG
message below)
On/Off
Board Test to Clear Value
Continued on next page