Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-405CO-TRK (CO Trunk)
3
Loop Around and Conference Circuit Test (#33)
This test checks the reflective loop around and conference capabilities of a CO
port circuit. The test uses 404-Hz, 1004-Hz, and 2804-Hz tones. Each tone is
transmitted separately through the loop and checked.
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted. Use the display port PCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait
until the port is idle before retesting.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times..
Any FAIL The NPE of the tested port was found to be transmitting in error. This
causes noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port is correctly using its allocated time slots. User-reported troubles
on this port should be investigated by using other port tests and by
examining trunk or external wiring.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the
board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
between the internal ID and the port.
Table 3-175. TEST #6 NPE Crosstalk Test — Continued
Error
Code
Te s t
Result Description/ Recommendation
Continued on next page