DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-163monitor health
2
CP
Proportion of the CPU currently dedicated to call processing. This
occupancy has priority over SM and IDLE occupancy categories and
takes processor time away from these occupancy categories, if
needed. This percentage is rounded to the nearest integer, therefore 0
percent means that the occupancy is less than one half of a percent.
Idle
Proportion of the CPU currently available. This percentage is rounded
to the nearest integer, therefore 0 percent means that the occupancy
is less than one half of a percent.
Active SPE
Currently-active processor complex. When the active processor
complex is locked on-line with lock switching on DUPINT, the “lock”
option displays; otherwise, “auto” displays.
Duplicated?
Duplication status of the SPE (n).
SPE Power
Current power source for the processor complex. The normal state is
“commercial”. When commercial power is unavailable, in-use battery
backup is indicated with “backup”.
Time Source
Current timing source is displayed. The display values for this field
vary according to timing sources selected. If the site administers the
optional Stratum-3 hardware, “external” displays and “internal”
displays when an internal source, such as a tone clock, is used.
Primary and secondary timing sources must be administered when
using the Stratum-4 option.
“primary” = primary administered source is in use
“secondary” = secondary administered source is in use.
“local” = neither the primary or secondary sources are in use.
# Logins
Number of current users.
Cab
Assigned cabinet number, ranging from 1 to the highest cabinet
number in the system.
Emerg Trans
Current setting of the emergency transfer switch for each cabinet. Five
options are available: auto-on (“auto+” or “a+”), auto-off (“auto-” or
“a-*, “on”, “off”, and “n.a.”. If “auto+” or “auto-” option are enabled,
emergency transfers automatically activate when cabinets fail (“+”
indicates that emergency transfer is activated, while “-” indicates that
emergency transfer is inactive). When “on” is displayed, emergency
transfer automatically activates. The “off” option shows that cabinets
cannot activate emergency transfers. In duplicated SPE systems,
switch settings for both processors of the PPN (cabinet 1) display. In
this case, “auto+” is abbreviated “a+”, “auto-” is d “a-”, and “off” is
“of”. “on” does not changed. If “n.a.” displays, emergency transfer
switch settings are not available.
Mj
Number of major alarms associated with the cabinet. An asterisk fills
the field when the number exceeds 99.
Mn
Number of minor alarms associated with the cabinet. An asterisk fills
the field when the number exceeds 99.