DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-729ISDN-SGR (ISDN-PRI Signaling Group)
3
Secondary Signaling Link Hardware Check (#639)
The ISDN-PRI Signaling Group D-Channel port depends on the health of the
DS1/UDS1 Interface circuit pack on which it resides. This test will fail if there are
problems with either the ISDN-PRI Primary D-channel port or the DS1/ UDS1
circuit pack. If there are problems with the ISDN-PRI Secondary Signaling
Channel port (ISDN-PLK), also investigate the DS1/UDS1 circuit pack.
See Figure 3-23
for DS1 connections, Figure 3-24 for UDS1 connections.
PASS A message was composed and sent to the Far-end switch. The ISDN PRI
specification allows up to two minutes for a reply.
1. Check the Error Log for ISDN-SGR (ISDN-PRI Signaling Group) for
errors of type 2305 for evidence of a Remote Layer 3 Query failure. If no
new errors were logged since this test was run, then this switch and the
Far-end switch processor can exchange call control messages.
2. If there is still a problem with a particular DS1 ISDN Trunk or PRI
Endpoint Port (B-channel), busyout the trunk or port and run the long
test sequence, paying particular attention to the results of Test #258
(ISDN Test Call).
Table 3-307. TEST #639 Secondary Signaling Link Hardware Check
Error
Code
Te s t
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1132 ABORT The Secondary D-channel is not administered for this Signaling Group.
This is a NORMAL ABORT. Only a Primary D-channel must be
administered for a Signaling Group.
Continued on next page
Table 3-306. TEST #637 Remote Layer 3 Query — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page