DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-313BRI-SET, ASAI-ADJ, BRI-DAT
3
BRI Set Audits Test (#630)
This is a series of two tests which are classified as audits. The switch sends
messages to the BRI endpoint to perform the following tests:
Ringer Audit - This audit ensures that both the switch and the endpoint
agree as to the current state of the endpoint’s ringer.
Lamps Audit - This audit ensures that both the switch and the endpoint
agree as to the current state of the endpoint’s lamps.
Call Activity Audit - This audit ensures that the state of calls is consistent
between the switch and the endpoint.
2068 ABORT The endpoint has rejected the switch sent application
message. This indicates that the endpoint does not support
the ISDN-BRI Management and Maintenance Procedure for
Endpoint Service Messages.
1. Use the change station extension command and change
the
MIMs Supported? field to n.
2069 ABORT The endpoint has returned an error response to the switch sent
application message.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2000 FAIL No response is received from the endpoint or the adjunct. For
BRI endpoints:
1. Consult the endpoint documentation to determine if
ISDN-BRI Management and Maintenance Procedures are
supported. If not supported, use the change station
extension command to change the MIMs Supported?
field to n. Use the busyout station extension and release
station extension commands to busyout and release the
endpoint to resolve any endpoint alarms resulting from
failure of this test.
2. If the endpoint supports these procedures and the test
continues to fail, assume the endpoint is defective and
replace it.
PASS The endpoint has successfully responded to the switch’s
application message.
Table 3-136. TEST #629 BRI Layer 3 Query — Continued
Error
Code
Te st
Result Description/ Recommendation
Continued on next page