Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-935PPP-PT (Control LAN Packet/Port)
3
TCP/IP Ping Test (#1281)
This non-destructive test fails if the endpoint fails to respond. Use this test to
check the circuitry in the data path for a peer-to-peer IP layer connection.
2100 ABORT Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
FAIL CLAN circuit pack detected test failure.
1. If the problem persists, reset the circuit pack (busyout board UUCSS,
reset board UUCSS, and release board UUCSS).
2. If the problem persists, replace the circuit pack.
PASS Port circuitry functioning properly.
Table 3-403. TEST #1281 TCP/IP Ping Test
Error
Code
Te st
Result Description/ Recommendation
1, 2, 7,
11
ABORT Internal error
1. Retry the command at 1-minute intervals up to 3 times
2. Escalate if the problem persists.
1005 ABORT Test configuration is incorrect.
1. Verity PPP link is in-service (status clan-port UUCSSpp or status link
n
).
2. Repeat the test.
3. Escalate if the problem persists.
1124 ABORT ppp link is not enabled.
1. Verify that the ppp link is enabled (status port UUCSSpp, status link
n
, or display data-module).
2. If the link is not enabled, enable the link (change data-module).
3. Repeat the test.
4. Escalate if the problem persists.
Continued on next page
Table 3-402. TEST #1275 SCOTCH Synchronous Looparound Test — Continued
Error
Code
Te st
Result Description/ Recommendation
Continued on next page