DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1115TIE-TRK (Tie Trunk)
3
This test may fail due to noise induced by adjacent electric power lines.
Customers having this problem should resolve it with their local power company.
To temporarily alleviate the alarm caused by the failure of this test, the test may
be disabled from the trunk administration Test field.
Table 3-492. TEST #33 Loop Around and
Conference Circuit Test
Error
Code
Te s t
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
7 ABORT The conference circuit test was aborted.
1. Retry the command at 1-minute intervals a maximum of 5 times.
129 ABORT The 404-Hz reflective loop around test aborted. Response to the test
request was not received within the allowable time period.
131 The 1004-Hz reflective loop around test aborted. Response to the test
request was not received within the allowable time period.
133 The 2804-Hz reflective loop around test aborted. Response to the test
request was not received within the allowable time period.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The trunk may
be busy with a valid call. Use the display trunk xx command to determine
the trunk group/member number of the port. Use the status trunk
command to determine the service state of the port. If the service state
indicates that the port is in use, the port is unavailable for certain tests. You
must wait until the port is idle before retesting.
1. If the port status is active, but the port is not in use (no calls), check
the Error Log for Error Type 1025 (see Error Log table for a description
of this error and required actions). The port may be locked up.
2. If the port status is idle, retry the command at 1-minute intervals a
maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors. Refer to TDM-BUS Maintenance to diagnose any
active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals a maximum of 5 times.
Continued on next page