Lucent Technologies 555-233-119 Home Theater Server User Manual


  Open as PDF
of 1872
 
DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-305status system
2
Output
The following example shows the output from the
status system all-cabinets
command.
Field descriptions
SPE
Switch Process Element (SPE) identifier (
1A
or
1B
)
MODE
SPE modes are different for simplex systems than for duplicated
systems. See SPE Modes section that follows.
SELECT SWITCH
SPE select switch position:
auto
: the switch is in the middle position and automatically
switches SPE depending upon conditions
<blank> always appears for the 1A SPE in a simplex system.
PE ALARMS -
MAJOR
Number of Major alarms associated with the SPE complex that
affect the fault severity level of this SPE.
SPE ALARMS -
MINOR
Number of Minor alarms associated with the SPE complex that
affect the fault severity level of this SPE.
TONE/CLOCK
Location of the tone-clock circuit pack (
1A
and
1B
).
SERVICE STATE
in
: Tone-Clock is installed and is in-service
out
: Tone-Clock failed certain maintenance tests and has been
removed from service
<blank> In simplex systems there is no B-carrier Tone-Clock,
and this field displays blank.
status system all-cabinets Page 1 of 3 SPE B
SYSTEM STATUS CABINET 1
SELECT SPE ALARMS TONE/ SERVICE SYSTEM SYSTEM
SPE MODE SWITCH MAJOR MINOR CLOCK STATE CLOCK TONE
1A active 0 2 1A in active active
SERVICE CONTROL DEDICATED SERVICE BUS ALARMS BUS OPEN BUS
TDM STATE CHANNEL TONES PKT STATE MAJOR MINOR FAULTS LEADS
1A in y n 1 in n n
1B in n y
EMERGENCY SELECT SERVICE CABINET
TRANSFER SWITCH EXP-LINK STATE MODE TYPE
1A auto-off - CMC
1B