DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-20Initialization and Recovery
1
Initialization and Recovery
When the system is initially powered up, or when an existing system experiences
a catastrophic fault that interrupts its basic functions, the system either initializes
or reboots.
Initialization
Upon initialization, no forms (not even Customer Options) are available until the
Offer Category is set. (The remote INADS channel is available.) To set the
customer options (INADS password only), do the following:
1. Enter
change system-parameters offer-options
(init and inads logins
only) and the following form displays:
Field descriptions
2. After these two fields are filled and you press Enter, the system displays:
WARNING: Activating Offer Category may set unchangeable
limits.
This is to let you know that the Offer Category along with the model
determine the system capacities (limits) and allowable hardware.
3. Select the
Submit option to submit the form.
4. Use the
save translations
command to make the changes permanent.
!
CAUTION:
To avoid potential loss of service, ensure that your system’s
translations are protected by saving them to the PCM/CIA card.
Offer category
Type either
A
or
B
.
Activate offer?
Type
y
if the entry for
Offer category
is correct and press Tab.
Type
n
if there is an error in the
Offer category
field and press
Tab . Re-enter the correct Offer Category.
change system-parameters offer-options
OFFER OPTIONS FORM
Offer Category: _
Activate Offer? _
WARNING: Need to save translations and reboot to make the change permanent.