DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-130ATM Tips
1
Figure 1-58. List sys-link screen
Ensure that the fields have the values indicated below.
2. Enter
show switch circuittable
on the A500 console. Figure 1-59
shows
the screen output.
Figure 1-59. A500: show switch circuit screen
Link Type/
Channel
One PACL to each TN230X in either a PPN or an EPN, and
one EAL to each TN230X in an EPN.
State up
list sys-link
SYSTEM LINKS INFORMATION
Location Link Type/ State Current Faulted Last Fault
Channel Path Path Recorded
02A0101 EAL up present present 12/06/1997 16:20
01B0202 PACL up present present 12/06/1997 16:17
02A0102 PACL up present present 12/06/1997 16:20
A500:show switch circuit
_______________________________________________________
| Input | Output | Connection |
| port vpi vci| port vpi vci| type class parameters |
|______________|______________|_________________________|
A1.1 0 5 Self 0 1 pp UBR ppd on
A1.1 0 32 A1.2 0 32 pp VBRnrt pcr=5729 /scr=5729 /mbs=17187
A1.1 0 35 A1.2 0 35 pmp CBR pcr=173
A1.2 0 5 Self 0 2 pp UBR ppd on
A1.2 0 32 A1.1 0 32 pp VBRnrt pcr=5729 /scr=5729 /mbs=17187
A1.2 0 34 A1.1 0 34 pmp CBR pcr=173
Self 0 1 A1.1 0 5 pp UBR ppd on
Self 0 2 A1.2 0 5 pp UBR ppd on
_________________________________________________________