DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-345CARD-MEM (Memory Card)
3
When the test passes, both directories are sane. If the memory card is a
system-upgrade memory card, the test is aborted. If the test fails, the broken or
missing directory cannot be rebuilt. As a result, all subsequent "write-to-memory
card" operations are blocked. When an alarm is raised and Error Type 1025 for
CARD-MEM is active, replace the memory card.
Table 3-152. TEST #699 Memory Card Directory Recovery Test
Error
Code
Te st
Result Description/ Recommendation
1192 ABORT Contention error. Applications are accessing the memory card.
1. Wait 10 minutes for the applications to complete.
2. Retry the command at 1-minute intervals a maximum of 5 times.
2012
2106
2114
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2013
2100
none
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2110 ABORT No memory card is inserted.
1. Insert a formatted memory card into the slot at the Processor circuit
pack.
2. Retry the command at 1-minute intervals a maximum of 5 times.
2111 ABORT Inserted memory card cannot be recognized.
1. Insert a new formatted memory card into the slot at the Processor
circuit pack.
2. Retry the command at 1-minute intervals a maximum of 5 times.
2112 ABORT Internal system error The inserted memory card is a "system-upgrade"
memory card.
1. Replace the inserted memory card with a user’s memory card.
2. Retry the command at 1-minute intervals a maximum of 5 times.
2115 ABORT The memory card is write-protected.
1. Take the memory card out, flip the "write-protection" switch to the
"not-protected" position, and insert the memory card back into the slot.
2. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page